Extra-Max Energy Efficiency Series-ODP
| Output | 250HP ~ 500HP |
| Poles | 2, 4 & 6P |
| Frame Size | 445T ~ 5807UZ |
| Frequency | 60 Hz |
| Enclosure | ODP |
| Efficiency | Energy Efficient Efficiency (Meet EISA 2007) |
| Power | 3-Phase |
| Standard Voltage | 450V, 575V |
| Service Factor | 1.15 |
| Electrical Design | B |
| Insulation Class | F |
| Temp Rise | B Rise @ 1.15 S.F |
| Frame Material | Cast iron |
Super-Max NEMA Premium Efficiency Series-TEFC
| Output | 1HP ~ 500HP |
| Poles | 2, 4 & 6P |
| Frame Size | 140T ~ N5808 |
| Frequency | 60 Hz |
| Enclosure | TEFC |
| Efficiency | NEMA Premium Efficiency |
| Power | 3-Phase |
| Standard Voltage | 200-230/460V & 575V (200HP and above are 460 or 575V only) |
| Service Factor | 1.15 |
| Electrical Design | B |
| Insulation Class | F |
| Temp Rise | B Rise @ 1.0S.F |
| Frame Material | Cast iron |
Super-Max NEMA Premium Efficiency Series-ODP
| Output | 1HP ~ 500HP |
| Poles | 2, 4 & 6P |
| Frame Size | 140T ~ N5807N |
| Frequency | 60 Hz |
| Enclosure | ODP |
| Power | 3-Phase |
| Standard Voltage | 200-230/460V & 575V (200HP and above are 460 or 575V only) |
| Service Factor | 1.15 |
| Electrical Design | A or B |
| Insulation Class | F |
Supermax-841 Premium Efficiency Series
| Output | 1HP ~ 500HP |
| Poles | 2, 4 & 6P |
| Frame Size | 140T ~ N5808 |
| Frequency | 60 Hz |
| Enclosure | TEFC |
| Power | 3-Phase |
| Efficiency | NEMA Premium Efficiency |
| Power | 3-Phase |
| Standard Voltage | 460V, 575V (Single Voltage) |
| Service Factor | 1.15 |
| Electrical Design | B |
| Insulation Class | F with B Rise @ 1.0S.F |
Explosion Proof NEMA Premium Efficiency Series
| Output | 1HP ~ 200HP |
| Poles | 2, 4 & 6P |
| Frame Size | 140T ~ N5808 |
| Frequency | 60 Hz |
| Efficiency | NEMA Premium Efficiency |
| Power | 3-Phase |
| Efficiency | NEMA Premium Efficiency |
| Power | 3-Phase |
| Standard Voltage | 230/460V (Usable on 200V), 575V |
| Service Factor | 1.15 |
| Electrical Design | B |
| Insulation Class | F with B Rise @ 1.0S.F |
| Hazardous Locations | Division 1 class I, Group D, class II Group E,F & G |
| Frame Material | Cast Iron |
Close-Coupled Pump JM and JP Series
| Output | 0.75HP ~ 50HP |
| Poles | 2, 4 & 6P |
| Frame Size | 143JM/JP ~ 365JP |
| Frequency | 60 Hz |
| Enclosure | TEFC |
| Efficiency | 3-Phase |
| Efficiency | NEMA Energy Efficient (EPAct) |
| Power | 3-Phase |
| Standard Voltage | 230/460V (Usable on 200V), 575V |
| Service Factor | 1.15 |
| Electrical Design | B |
| Insulation Class | F with B Rise @ 1.0S.F |
| Frame Material | Cast Iron |
Round Body C-Face Premium Efficiency Series
| Output | 1HP ~ 75HP |
| Poles | 2, 4 & 6P |
| Frame Size | 143TC ~ 365TC |
| Frequency | 60 Hz |
| Enclosure | TEFC |
| Efficiency | NEMA Premium Efficiency |
| Power | 3-Phase |
| Standard Voltage | 208-230/460V & 575V |
| Service Factor | 1.15 |
| Electrical Design | B |
| Insulation Class | F with B Rise @ 1.0S.F |
| Frame Material | Cast Iron |
| Additional Info | CSA Certified for Division 2 class I, Group A.B.C.D Temp, Code T3C |
Rock Crusher Duty High Efficiency Motor
| Output | 125HP ~ 600HP |
| Poles | 4, 6, & 8P |
| Frame Size | 445T ~ N5810UZ |
| Frequency | 60 Hz |
| Enclosure | TEFC |
| Efficiency | TATUNG Standard Efficiency |
| Power | 3-Phase |
| Standard Voltage | 460V or 575V |
| Service Factor | 1.15 |
| Electrical Design | NEMA design C |
| Insulation Class | F with B Rise @ 1.0S.F |
| Frame Material | Cast Iron |
Industrial Duty TEFC Vertical Hollow Shaft Motors
| Output | 5HP ~ 200HP |
| Poles | 2, 4, & 6P |
| Frame Size | 210TP ~ 447TP |
| Frequency | 60 Hz |
| Enclosure | TEFC |
| Efficiency | TATUNG Standard Efficiency |
| Power | 3-Phase |
| Standard Voltage | 230V or 460V |
| Service Factor | 1.15 |
| Electrical Design | NEMA design B |
| Insulation Class | F with B Rise @ 1.0S.F |
| Frame Material | Cast Iron |
HARVEST SERIES TEFC Vertical Solid Shaft Motors (Premium Efficiency)
| Output | 5HP ~ 300HP |
| Poles | 4P |
| Frame Size | 213VP ~ 449VP |
| Frequency | 60 Hz |
| Enclosure | TEFC |
| Efficiency | NEMA Standard Efficiency |
| Power | 3-Phase |
| Standard Voltage | 30V/460V, 460V |
| Service Factor | 1.15 and up |
| Electrical Design | NEMA design B |
| Insulation Class | F with B temperature at S.F 1.0 |
| Frame Material | Cast Iron |
| Additional Info | High thrust Interchangeable with WPI |
HARVEST SERIES TEFC Vertical Hollow Shaft Motors (Premium Efficiency)
| Output | 5HP ~ 300HP |
| Poles | 4P |
| Frame Size | 213VP ~ 449VP |
| Frequency | 60 Hz |
| Enclosure | TEFC |
| Efficiency | NEMA Standard Efficiency |
| Power | 3-Phase |
| Standard Voltage | 30V/460V, 460V |
| Service Factor | 1.15 and up |
| Insulation Class | F with B temperature at S.F 1.0 |
| Frame Material | Cast Iron |
| Additional Info | High thrust Interchangeable with WPI |
TS21FN Series-TEFC
| Output | 400HP ~ 900HP |
| Poles | 2P ~ 10P |
| Frame Size | N5009~N6310 (NEMA / IMPERIAL) |
| Frequency | 60 Hz |
| Enclosure | Totally Enclosed Fan Cooled (TEFC) |
| Power | 3-Phase |
| Standard Voltage | 460V, 575V |
| Mounting | Horizontal Foot Mounted |
| Insulation | Class F |
| Temperature Rise | Class B (80°C by Resistance Method at S.F. 1.0) |
| Environment | Ambient Temperature 40°C |
TS21FNV Series-TEFC, Vertical
| Output | 400HP ~ 900HP |
| Poles | 4P ~ 10P |
| Frame Size | N5009~N6310 (NEMA / IMPERIAL) |
| Frequency | 60 Hz |
| Enclosure | Totally Enclosed Fan Cooled (TEFC) |
| Power | 3-Phase |
| Standard Voltage | 460V, 575V |
| Mounting | Vertical Flange Mounted |
| Insulation | Class F |
| Temperature Rise | Class B (80°C by Resistance Method at S.F. 1.0) |
| Environment | Ambient Temperature 40°C |
TS21FN TEFC Series
| Output | 150HP ~ 2500HP |
| Poles | 2P ~ 10P |
| Frame Size | N5009~N8810 (NEMA / IMPERIAL) |
| Frequency | 60 Hz |
| Enclosure | Totally Enclosed Fan Cooled (TEFC) |
| Standard Voltage | 2300V, 4160V, 6600V, 11000V |
| Mounting | Horizontal Foot Mounted |
| Insulation | Class F |
| Temperature Rise | Class B (80°C by Resistance Method at S.F. 1.0) |
| Environment | Ambient Temperature 40°C |
TW21TN TEAAC Series
| Output | 500HP ~ 6000HP |
| Poles | 2P ~ 8P |
| Frame Size | N3512 ~ N5620 (NEMA / IMPERIAL) |
| Frequency | 60 Hz |
| Enclosure | Totally Enclosed Fan Cooled (TEFC) |
| Standard Voltage | 2300V, 4160V, 6600V, 11000V |
| Mounting | Horizontal Foot Mounted |
| Insulation | Class F |
| Temperature Rise | Class B at S.F. 1.0 / Class F at S.F. 1.15 (by Resistance Method) |
| Environment | Ambient Temperature 40°C |
TS21DN ODP(WP I) Series
| Output | 450HP ~ 2500HP |
| Poles | 2P ~ 8P |
| Frame Size | 5810 / 6310 / 6810 (NEMA / IMPERIAL) |
| Frequency | 60 Hz |
| Enclosure | Weather Protected Type II (WPII) |
| Standard Voltage | 2300V, 4000V, 4160VV |
| Mounting | Horizontal Foot Mounted |
| Insulation | Class F |
| Temperature Rise | Class B at S.F. 1.0 / Class F at S.F. 1.15 (by Resistance Method) |
| Environment | Ambient Temperature 40°C |
TW21TN WP II Series
| Output | 500HP ~ 7500HP |
| Poles | 2P ~ 8P |
| Frame Size | N3512 ~ N5620 (NEMA / IMPERIAL) |
| Frequency | 60 Hz |
| Enclosure | Totally Enclosed Fan Cooled (TEFC) |
| Standard Voltage | 2300V, 4160V, 6600V, 11000V |
| Mounting | Horizontal Foot Mounted |
| Insulation | Class F |
| Temperature Rise | Class B at S.F. 1.0 / Class F at S.F. 1.15 (by Resistance Method) |
| Environment | Ambient Temperature 40°C |
TS21FNV Series: Vertical, #5009-#8810
| Output | 150HP ~ 2500HP |
| Poles | 4P ~ 10P |
| Frame Size | N5009~N8810 (NEMA / IMPERIAL) |
| Frequency | 60 Hz |
| Enclosure | Totally Enclosed Fan Cooled (TEFC) |
| Power | 3-Phase |
| Voltage | 2300V, 4160V, 6600V, 11000V |
| Mounting | Vertical Flange Mounted |
| Insulation | Class F |
| Temperature Rise | Class B (80°C by Resistance Method at S.F. 1.0) |
| Environment | Ambient Temperature 40°C |
TW21TNV TEAAC Vertical Series
| Output | 400HP ~ 2500HP |
| Poles | 4P ~ 8P |
| Frame Size | N3511V ~ N5014V (IMPERIAL) |
| Frequency | 60 Hz |
| Enclosure | Weather Protected Type I |
| Voltage | 2300V, 4160V, 6600V, 11000V |
| Voltage | 2300V, 4160V, 6600V, 11000V |
| Mounting | Vertical Flange Mounted | Insulation | Class F |
| Temperature Rise | Class B at S.F. 1.0 / Class F at S.F. 1.15 (by Resistance Method) |
| Environment | Ambient Temperature 40°C |
TW21TNV WP II Vertical Series
| Output | 500HP ~ 3000HP |
| Poles | 4P ~ 8P |
| Frame Size | N3511V ~ N5014V (IMPERIAL) |
| Frequency | 60 Hz |
| Enclosure | Weather Protected Type II |
| Voltage | 2300V, 4160V, 6600V, 11000V |
| Voltage | 2300V, 4160V, 6600V, 11000V |
| Mounting | Vertical Flange Mounted | Insulation | Class F |
| Temperature Rise | Class B at S.F. 1.0 / Class F at S.F. 1.15 (by Resistance Method) |
| Environment | Ambient Temperature 40°C |
Large Vertical TW21TV Series: #560 & Above
| Output | 2000kW ~ 7500kW |
| Poles | 4P and above |
| Frame Size | 560 and above |
| Frequency | 50Hz, 60Hz |
| Enclosure | Totally Enclosed Air to Air Cooled (TEAAC) Totally Enclosed Water to Air Cooled (TEWAC) Weather Protected Type I and Type II |
| Voltage | 3000V – 11000V |
| Mounting | Vertical Flange Mounted (Solid & Hollow Shaft) | Insulation | Class F |
| Temperature Rise | Class B at S.F. 1.0 / Class F at S.F. 1.15 (by Resistance Method) |
| Environment | Ambient Temperature 40°C |


Tatung Motors