Class 1, Division 2 – Single Phase, Hazardous Location Motors

Currently there are no manufacturers that make or certify Division II single phase motors.


Dietz can produce non-agency certified Division 2 single phase motors. These motors are explosion proof construction. The centrifugal switch is replaced with an intrinsically safe Sinpac solid state switch, starting and running capacitors are internal to the motor. These motors are also one frame size larger, or one rating larger in order to produce a cooler running motor. All Division 2 recommendations, and practices are observed. These motors will have Dietz nameplates rated for Class 1 Division 2, Groups B, C, D.

These motors are available:

  • 0.25 – 5HP
  • 1200, 1800, 3600RPM
  • 1.0SF
  • 115/230VAC
  • Sinpac Solid State Switch
  • Internal Capacitors
  • T2C – T4 Temperature Code
  • Klixon Thermal protection available as an option
  • 50 or 60HZ available
  • Three Year Warranty
  • Explosion Proof Terminal Box
Motor

Ready to get started?

Contact us with your information. Our team will provide you with a customized quote.

Contact Us